Yangzhou Fongming Cable Factory

Yangzhou Fongming Cable Factory

How to improve the passing rate of fire test for fire-resistant cable

2018 06/28

How to improve the passing rate of fire test for fire-resistant cable. From the aspects of selection of raw materials, conductors, production process control.

1. Mica with three types, synthetic mica, phlogopite, muscovite. Their respective quality performance is the best for synthetic mica, and the muscovite is the worst. For small size cables, synthetic mica tape must be selected for wrapping. The mica tape layer cannot be used, and long-term storage of the mica tape is easy to absorb moisture, so the temperature and humidity of the surrounding environment must be taken into account when storing the mica tape.

2. When using mica tape wrapping equipment, the stability performance should be good. The wrapping angle should preferably be 300-400, and the mica tape should be evenly packed around. All guide rollers and rods touched by the equipment should be smooth and neat. , The tension is not easy to be too great, the side plates and barrels of the collection tooling wheel are flat and smooth.

3. For circular cores with axial symmetry, the mica tapes are tight in all directions after wrapping, so a round compacted conductor should be used for the conductor structure of the fire-resistant cable.

Yangzhou FongMing Cable Factory, special cable expert around you.